Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add filters








Language
Year range
1.
Chinese Journal of Immunology ; (12): 1453-1457,1463, 2017.
Article in Chinese | WPRIM | ID: wpr-657725

ABSTRACT

Objective:To investigate the mechanism of BCYRN1 regulating miR-503 through Notch1 signaling pathway in the migration and invasion of lung cancer. Methods:The expression of BCYRN1 and miR-503 in different lung cancer cell lines were detected by qPCR. Immunofluorescence and qPCR were used to detect the transfection efficiency of lentivirus BCYRN1 + siRNA transfected lung cancer cells. Double luciferase reporter gene was used to detect the interaction between BCYRN1 and miR-503. Transwell invasion test and scratch test were used to detect the invasion and migration of lung cancer cells after silencing BCYRN1. Western blot was used to detect the expression of Notch1 signaling pathway silence BCYRN1. The effect of silencing BCYRN1 on lung cancer cells in nude mice was measured by subcutaneous tumor formation in nude mice. Results:The expression level of BCYRN1 was the highest in lung cancer cell H1299,and the expression level of miR-503 was relatively high. Immunofluorescence and mRNA levels demonstrated that BCYRN1 + siRNA lentivirus could be effectively transfected into H1299 cells;BCYRN19 binds specifically to the 3′-UTR of miR-503;silencing BCYRN1 could inhibit the invasion and migration of lung cancer H1299 cells;the expression of Notch1 pathway protein was down-regulated after silencing BCYRN1. Compared with NC group,tumor volume and weight of BCYRN1-siRNA group were significantly decreased. Conclusion:BCYRN1 can target the regulation of miR-503 through Notch1 signaling pathway in the invasion and migration of lung cancer H1299 cells.

2.
Chinese Journal of Immunology ; (12): 1453-1457,1463, 2017.
Article in Chinese | WPRIM | ID: wpr-660094

ABSTRACT

Objective:To investigate the mechanism of BCYRN1 regulating miR-503 through Notch1 signaling pathway in the migration and invasion of lung cancer. Methods:The expression of BCYRN1 and miR-503 in different lung cancer cell lines were detected by qPCR. Immunofluorescence and qPCR were used to detect the transfection efficiency of lentivirus BCYRN1 + siRNA transfected lung cancer cells. Double luciferase reporter gene was used to detect the interaction between BCYRN1 and miR-503. Transwell invasion test and scratch test were used to detect the invasion and migration of lung cancer cells after silencing BCYRN1. Western blot was used to detect the expression of Notch1 signaling pathway silence BCYRN1. The effect of silencing BCYRN1 on lung cancer cells in nude mice was measured by subcutaneous tumor formation in nude mice. Results:The expression level of BCYRN1 was the highest in lung cancer cell H1299,and the expression level of miR-503 was relatively high. Immunofluorescence and mRNA levels demonstrated that BCYRN1 + siRNA lentivirus could be effectively transfected into H1299 cells;BCYRN19 binds specifically to the 3′-UTR of miR-503;silencing BCYRN1 could inhibit the invasion and migration of lung cancer H1299 cells;the expression of Notch1 pathway protein was down-regulated after silencing BCYRN1. Compared with NC group,tumor volume and weight of BCYRN1-siRNA group were significantly decreased. Conclusion:BCYRN1 can target the regulation of miR-503 through Notch1 signaling pathway in the invasion and migration of lung cancer H1299 cells.

3.
International Eye Science ; (12): 1249-1253, 2017.
Article in Chinese | WPRIM | ID: wpr-641293

ABSTRACT

AIM: To compare the accuracy of intraocular lens(IOL)power calculations by using five formulas(Haigis, SRK-T, Hoffer Q, Holladay-1, SRK-Ⅱ)in eyes with long axial lengths in order to improve the accuracy of predicating IOL powers.METHODS: Fifty-one eyes of 51 cases of age-related cataract and with mild long axial(24.5mm27mm) were collected who`s optical biometry were performed by the Zeiss IOL Master500 before operation.They underwent regular phacoemulsification and posterior chamber IOL implantation.The actual postoperative refraction was measured with the methods of phoropter and subjective optometry 3mo after surgery.Then we compared the differences of the predicted and actual postoperative refraction of the five formulas in each group.RESULTS: In the mild axial lengths cases, the differences between SRK Ⅱ formula and the other four formulas were statistically significant (P0.05).In the moderate and severe long axial lengths cases, the differences between SRK Ⅱ formula and the other four formulas were statistically significant (P0.05).The differences of all the five formulas between the two groups were statistically significant (P<0.05).CONCLUSION: In the mild axial lengths cases, Haigis, SRK-T, Hoffer Q, Holladay-1 performed well.In the moderate and severe long axial lengths cases, Haigis, SRK-T and Holladay-1 performed better than other formulas.The accuracy of all the five formulas decreases as the axial length getting longer.

4.
International Eye Science ; (12): 1055-1059, 2017.
Article in Chinese | WPRIM | ID: wpr-641224

ABSTRACT

AIM: To research the correlation factor of the anterior segment values of eyes with different axial lengths.METHODS: In this study, 697 cases 697 eyes were included.According to axial length we divided all the cases into short axial length group, normal axial length group, mild long axial length group, moderate long axial length group and severe long axial length group.The relevant indicators of the anterior segment values of patients in the five groups was comparatively analyzed.RESULTS: In the short axial length group, the anterior chamber volume (ACV) showed a significantly negative correlation with age;anterior chamber depth (ACD) showed a significantly negative correlation with age.In the normal axial length group, the ACV showed a significantly negative correlation with age and a significantly positive correlation with axial length(AXL);the anterior chamber angle (ACA) showed a significantly negative correlation with age and a significantly positive correlation with AXL, and a significantly positive correlation with corneal curvature;the ACD showed a significantly negative correlation with age and a significantly positive correlation with AXL.In the mild long axial length group, the ACV showed a significantly negative correlation with age and a significantly positive correlation with AXL, and a significantly negative correlation with corneal curvature;the ACA showed a significantly negative correlation with age and a significantly positive correlation with AXL, and a significantly positive correlation with corneal curvature;the ACD showed a significantly negative correlation with age and a significantly positive correlation with AXL.In the moderate long axial length group, the ACV showed a significantly negative correlation with age;the ACA showed a significantly positive correlation with AXL;the ACD showed a significantly positive correlation with AXL.In the severe long axial length group, the ACV showed a significantly negative correlation with age.There were no significant differences on ACV, ACA and ACD among mild long axial length group, moderate long axial length group and severe long axial length group (P>0.05), while the difference between other groups was significant (P<0.05).CONCLUSION: There has a correlation between the anterior chamber values (ACV, ACA, ACD) age and AXL for eyes which AXL were 22-27mm, while the correlation would disappear as the AXL became shorter or longer.There was a significant growth trend of anterior chamber values for eyes with AXL <27mm.

5.
Ophthalmology in China ; (6)1993.
Article in Chinese | WPRIM | ID: wpr-679896

ABSTRACT

Objective To explore the clinical application and outlook of anterior segment observation with Stratus optical coherence tomography(Stratus OCT).Design Prospective case series.Participants 56 eyes in 38 patients with primary angle closure glaucoma (PACG).Methods Morphological changes of anterior chamber angle (ACA) were observed with Stratus OCT before and 4 weeks after laser iridectomy.Opening status of ACA were described and measured with Photoshop software.Main Outcome Measures Opening degree of ACA and ratio of anterior chamber depth to thickness of cornea.Results To a great deal of extent,Stratus OCT could be used to observe the appearance of ACA. Clear images of ACA could be acquired.The ACA before laser was (15.67?5.33) degree and significantly reopened to(26.56?8.17) degree after laser iridectomy (P=0.000).The ratio of anterior chamber depth to thickness of cornea was also changed from (0.39?0.13) pre-treatment to (0.89?0.32) pest-treatment(P=0.000).Conclusions Stratus OCT could be applied to observe the changes of opening degree of ACA easily.The standard of quantization should be consummated in the future.

SELECTION OF CITATIONS
SEARCH DETAIL